Description
Hipot Analyzer Model 19055/19055-C
Description
The Chroma 19055 Series Hipot Analyzer is designed for Hipot test and analysis. It has a maximum output power of 500VA, a maximum AC output of 5kV/100mA, and Floating output for EN50191 requirements. (Please refer to the application notes for more detail information.)
The 19055-C includes ACW/DCW/IR tests, but also has a new measurement technology; Corona Discharge Detect ion (CDD). In addition, the Breakdown Voltage (BDV) Analysis can detect faults as follows;
Corona discharge Start Voltage (CSV)
Flashover Start Voltage (FSV)
Breakdown Voltage (BDV)
The Chroma 19055 series also has both High Frequency Contact Check (HFCC) and Open Short Check (OSC) functionality. This increases the test reliability and efficiency significantly through application of the contact check during the Hipot test.
The Chroma 19055 series is equipped with a large LCD screen which is convenient for the user to operate and judge. In addition, a GFI human protection circuit and Floating output design prevents exposing users to electrical hazards.
Specifications
- 500VA output power
- Floating output complies with EN50191
- Corona Discharge Detection (CDD, 19055-C only)
- Flashover Detection
- Breakdown Voltage (BDV) Analysis
- High Frequency Contact Check (HFCC)
- Open Short Check (OSC)
- Ground Fault Interrupt
- Standard RS-232 & HANDLER interface
- Optional GPIB interface
- Key lock when fail
- Programmable voltage & test limit
- Support for the A190301 8HV Scanning Box
Functions
- Hipot
- AC 5kV/100mA
- DC 6kV/25mA
- Insulation
- 5kVmax
- 1MΩ~50GΩ
Applications
Motor
The 19055 Series Hipot Analyzers with 500VA output power can be used to test and analyze the high power withstand voltage and leakage current for products like motor stators and rotors with larger parasitic capacitance.
Transformer
When a power transformer is used under normal voltage, Corona discharge from the primary side could cause damage to nearby components. Corona Discharge Detection (CDD), which is a function of 19055-C, can be used to detect this discharge during the design phase for improvement of product quality. Corona Discharge Detection (CDD) can also be used for coil-to-coil or coil-to ground tests to eliminate winding insulation failure due to Corona discharge
Informasi Penjualan
Temukan informasi penjualan produk Chroma Hipot Analyzer Model 19055/19055-C dengan mengubungi contact person kami atau dengan mengirimkan quotation barang tersebut. Untuk permintaan presentasi dan penjelasan lebih lanjut mengenai produk tersebut, hubungi kontak Sarana lab distributor Chroma di Indonesia.